SIEMENS


Skip over Site Identifier

Healthcare USA

Close Site Id Layer

new

 

about

Version: V6.0
DB: Nov 2019
 

related

Version: V1.0 DB: Aug 2005
Version: V2.0 DB: Aug 2006
Version: V3.0 DB: Jul 2008
Version: V4.0 DB: Apr 2009
Version: V5.0 DB: Jun 2014


Skip over Language Switch

Language switch

  • English
  • Deutsch

Skip over Generic Navigation

  • Contact

Skip over Help

Help


Choice of configuration
Client/Send stationCommunication/ SecurityServer/ Receiver stations
CPU
nothing selected
 CPU 1215C
 CPU 1513-1PN
 CPU 1516-3PN/DP
 CPU 1518-4PN/DP
 CPU 1507S (IPC 427E)
 CPU 416-3PN/DP
Comm-Interface
nothing selected
 ---
 X1- (100Mbit)
 X3- (1000Mbit)
 X2- (1000Mbit)
 CP X1-P1 IE
CP
nothing selected
 ---
 CP 1243-1
 CP 1543-1
 CP 1543SP-1
 CP 443-1 OPC UA (Client)
Load due to program
nothing selected
 1 ms
 5 ms
 10 ms
 50 ms
Net topology (security)
nothing selected
 SC642 <-> SC642
 SC642 <-> 1..N CP 1543-1
 CP 1543-1 <-> 1..N CP 1543-1
 ---
 CP 1543-1 <-> 1..N CP 1543SP-1
 SC642 <-> 1..N CP 1543SP-1
Security Policy
nothing selected
 none
 TLS 1.2 (SOUC)
 IPSec (AES 256 SHA 256)
 Basic256SHA-Sign&Encrypt(OPC UA)
Communications service
nothing selected
 OUC (TCP)
 OUC (ISOonTCP)
 OUC (UDP)
 S7-Comm (PUT)
 S7-Comm (BSEND)
 OPC UA Registered Write
 OPC UA Call Method (Input Param)
Data length [Bytes]
nothing selected
 100
 1000
 10000
 50000
 100000
Distribution of variables
nothing selected
 1 Symbol as Array of [1..n] Bytes
 N Symbols of type DINT
 Array of [1..n] Bytes
Num symbols
not avaiable
CPU
nothing selected
 CPU 1513-1PN
 CPU 1511-1PN
 CPU 1516-3PN/DP
 CPU 1518-4PN/DP
 CPU 1515SP PC2
 CPU 1507S (IPC 427E)
 CPU 1214C
 CPU 1510SP-1PN
Comm-Interface
nothing selected
 ---
 X1- (100Mbit)
 X3- (1000Mbit)
 X2- (1000Mbit)
 CP X1-P1 IE
CP
nothing selected
 ---
 CP 1243-1
 CP 1543-1
 CP 1543SP-1
Load due to program
nothing selected
 10 ms
 50 ms
 1 ms
 5 ms
Number of stations
nothing selected
 1
 4
 8
 16
 
Performance Requirements
Transfer times
TransTime_min[ms]
Nothing set

must be of type integer
TransTime_avg[ms]
Nothing set

must be of type integer
TransTime_max[ms]
Nothing set

must be of type integer
 
Chosen topology
Load due to program:nothing selected
Security:nothing selected
Communications services:nothing selected
Data length [Bytes]:nothing selected
Load from program in OBI (receiver):nothing selected
Number of receiver stations:nothing selected
 

Results: 9538 of 9538      Download results (*.csv)

Show columns

S-CPUS-CPS-Prg-LoadSecurity CompSecurityPolicyDataLengthVar. distributionNumSymbolsR-CPUR-CPR-Prg-LoadNum StationsS-Cycle time avg[ms]R-Cycle time avg[ms]TransTime_avg[ms]
CPU 1518-4PN/DP---1 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1110,6
CPU 1518-4PN/DP---5 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1510,67
CPU 1518-4PN/DP---5 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1510,68
CPU 1518-4PN/DP---10 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms110,110,69
CPU 1518-4PN/DP---5 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1510,72
CPU 1518-4PN/DP---10 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms110,110,75
CPU 1518-4PN/DP---1 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1110,77
CPU 1518-4PN/DP---10 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms110,110,79
CPU 1518-4PN/DP---1 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1110,79
CPU 1518-4PN/DP---10 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms110,111,02
CPU 1518-4PN/DP---1 ms---none10001 Symbol as Array of [1..n] Bytes1CPU 1518-4PN/DP---10 ms11101,14
CPU 1518-4PN/DP---1 ms---none10001 Symbol as Array of [1..n] Bytes1CPU 1518-4PN/DP---1 ms1111,14
CPU 1518-4PN/DP---1 ms---none10001 Symbol as Array of [1..n] Bytes1CPU 1518-4PN/DP---5 ms1151,14
CPU 1518-4PN/DP---1 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1111,15
CPU 1518-4PN/DP---5 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1511,15
CPU 1518-4PN/DP---5 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms4511,16
CPU 1518-4PN/DP---10 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms110,111,17
CPU 1518-4PN/DP---1 ms---none1000Array of [1..n] Bytes---CPU 1518-4PN/DP---1 ms1111,17
CPU 1518-4PN/DP---1 ms---Basic256SHA-Sign&Encrypt(OPC UA)10001 Symbol as Array of [1..n] Bytes1CPU 1518-4PN/DP---10 ms11101,17
CPU 1518-4PN/DP---1 ms---Basic256SHA-Sign&Encrypt(OPC UA)10001 Symbol as Array of [1..n] Bytes1CPU 1518-4PN/DP---1 ms1111,17
1 |  2 |  3 |  4 |  5 |  6 ...477
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Name of columnDescription
S-CPU CPU Typ (Sender/Client)
S-CPUFW Firmwarestand CPU (Sender/Client)
S-CP CP Typ (Sender/ Client)
S-CPFW Firmwarestand CP (Sender/Client)
S-CommInt HW-Communication Interface (Sender/Client)
S-Prg-Load Last durch Programm im OB1 (Sender/Client)
Security Comp Security Komponente
SecurityPolicy Security level
Protocol Kommunikations-Protokoll
DataLength Anzahl Bytes pro Empfangs-/Serverstation
Var. distribution Verteilung der Variablen
NumSymbols Anzahl Symbole
R-CPU CPU-Typ (Empfänger/Server)
R-CPUFW Firmwarestand CPU (Empfänger/Server)
R-CommInt HW-Communication Interface (Empfänger/Server)
R-CP CP Typ (Empfänger/ Server)
R-CPFW Firmwarestand CP (Empfänger/ Server)
R-Prg-Load Last durch Programm im OB1 (Empfänger/ Server)
Num Stations Anzahl Empfangs-/Serverstationen
S-Cycle time min[ms] minimum OB1 send cycle time [ms]
S-Cycle time avg[ms] average OB1 send cycle time [ms]
S-Cycle time max[ms] maximum OB1 send cycle time [ms]
R-Cycle time min[ms] minimum OB1 receive cycle time [ms]
R-Cycle time avg[ms] average OB1 receive cycle time [ms]
R-Cycle time max[ms] maximum OB1 receive cycle time [ms]
TransTime_min[ms] minimum transmission time [ms]
TransTime_Q25[ms] 25% quartile transmission time[ms]
TransTime_avg[ms] average transmission time [ms]
TransTime_Q75[ms] 75% quartile transmission time[ms]
TransTime_max[ms] maximum transmission time [ms]
 
siemens.com Global Website |
© Siemens AG 2002-2024 -
Corporate Information | Privacy Policy | Terms of Use | Digital ID