SIEMENS


Skip over Site Identifier

Healthcare USA

Close Site Id Layer

nouveau

 

about

Version: V8.1
DB: Jan 2011
 

related

Version: V2.0 DB: Apr 2006
Version: V3.0 DB: Sept 2006
Version: V4.0 DB: Jun 2007
Version: V6.0 DB: Jul 2008
Version: V7.0 DB: Jun 2009
Version: V9.0 DB: Jul 2015


Skip over Language Switch

Language switch

  • English
  • Deutsch
  • Français
  • Italiano
  • Español
  • 中文

Skip over Generic Navigation

  • Contact

Skip over Help

Help


Choix de la configuration
Contrôleur IORéseauPériphérie
CPU
nothing selected
 IM 151-8 PN/DP CPU
 CPU 314C-2PN/DP
 CPU 315-2DP
 CPU 1215C
 CPU 317-2PN/DP (OCM Prio)
 CPU 319-3PN/DP (OCM Prio)
 CPU 414-2DP
 CPU 414-3PN/DP
 CPU 416-3PN/DP
 S7-mEC EC31-RTX
 PC477C-RTX
 PC477C-HMI/RTX
 PC277D-RTX
 PC277D-HMI/RTX
 PC677C-RTX
 PC677C-HMI/RTX
CP
nothing selected
 ---
 CP 1616
 CP343-1 Adv (GX30)
 CP443-1 Adv (GX20)
Charge par programme
nothing selected
 0 ms
 50 ms
 50ms + LARGE
 50ms + ENHANCED
 6 ms
 6ms + LARGE
 6ms + ENHANCED
Branchement secteur
nothing selected
 wired
 IE/PB Link PN-IO
 SCALANCE W786-2RR
Nombre de clients WLAN
nothing selected
 0
 1
 4
 8
 16
Baudrate IE/PB-Links
nothing selected
 1,5 MBaud
 12 MBaud
 ---
Type
nothing selected
 ET 200M DP HF
 ET 200S DP HF
 ET 200S PN HF
 ET 200S PN HS
 ET 200M PN HF
Nombre de stations
nothing selected
 1
 8
 16
 32
 60
Octets ES par station
nothing selected
 4
 16
 30
 32
Charge sur le réseau
Communication de donnéesEngineeringHMI
CPU
nothing selected
 CPU 414-3PN/DP
 ---
CP
nothing selected
 ---
 CP 443-1 (EX20)
Nombre des stations de réception
nothing selected
 0
 1
 8
Service de communication
nothing selected
 AGSEND (IsoOnTCP)
 BSEND (S7-Protocol)
 TSEND (IsoOnTCP)
 ---
 PUT(S7-Protocol)
Taille data [octets]
nothing selected
 0
 8
 1024
PG
nothing selected
 ---
 PG
HMI
nothing selected
 ---
 KTP 600 PN Basic
Nombre de stations
nothing selected
 0
 1
 4
Volume de configuration des appareils IHM
nothing selected
 ---
 Small
 Large
 
Performances prédéfinies
Temps de réponseTemps de commandeTemps de mise à jour
T Rea min [ms]
Nothing set

must be of type integer
T Rea max [ms]
Nothing set

must be of type integer
T Rea Alrm min[ms]
Nothing set

must be of type integer
T Rea Alrm max[ms]
Nothing set

must be of type integer
T HMI op. min [ms]
Nothing set

must be of type integer
T HMI op. max [ms]
Nothing set

must be of type integer
T PPC op. min [ms]
Nothing set

must be of type integer
T PPC op. max [ms]
Nothing set

must be of type integer
T HMI upd. min [ms]
Nothing set

must be of type integer
T HMI upd. max [ms]
Nothing set

must be of type integer
T PPC upd. min [ms]
Nothing set

must be of type integer
T PPC upd. max [ms]
Nothing set

must be of type integer
 
Configuration choisie
Charge par programme:nothing selected
Nombre de clients WLAN:nothing selected
Nombre de stations:nothing selected
Octets ES par station:nothing selected
Charge par programme (récepteur):6 ms
Nombre des stations de réception :nothing selected
Service de communication:nothing selected
Taille data [octets] :nothing selected
Nombre de stations HMI :nothing selected
Volume de configuration des appareils IHM:nothing selected
 

Résultats: 10540 de 10540      Télécharger résultats (*.csv)

Montrer colonnes

CPUPrg-LoadCPPGHMINum HMI StationsHMI-PrgLoadDeviceNum devicesIO-BytesT Rea min [ms]T Rea max [ms]T Rea Alrm min[ms]T Rea Alrm max[ms]T ReaSynch min[ms]T ReaSynch max]ms]TransTime_min[ms]TransTime_max[ms]
S7-mEC EC31-RTX0 ms---------0---ET 200M PN HF141,43,72,44,4    
PC677C-RTX0 ms---------0---ET 200M PN HF141,43,62,34    
CPU 317-2PN/DP (OCM Prio)0 ms---------0---ET 200M PN HF141,33,63,66,2    
PC677C-RTX0 msCP 1616------0---ET 200M PN HF1642,33,12,34,1    
PC477C-RTX0 ms---------0---ET 200M PN HF142,32,92,34,1    
CPU 314C-2PN/DP0 ms---------0---ET 200M PN HF141,33,43,36,8    
CPU 416-3PN/DP0 ms---------0---ET 200M PN HF1642,432,44,5    
CPU 314C-2PN/DP0 ms---------0---ET 200M PN HF1642,53,13,36,3    
CPU 317-2PN/DP (OCM Prio)0 ms---------0---ET 200M PN HF1641,73,33,36,4    
S7-mEC EC31-RTX0 ms---------0---ET 200M PN HF1642,73,42,34    
PC677C-RTX0 msCP 1616------0---ET 200M PN HF141,34,32,34,4    
PC277D-RTX0 ms---------0---ET 200M PN HF142,13,42,44,4    
CPU 414-3PN/DP0 ms---------0---ET 200M PN HF1642,73,32,24,4    
CPU 414-3PN/DP0 ms---------0---ET 200M PN HF142,83,32,45,2    
CPU 416-3PN/DP0 ms---------0---ET 200M PN HF142,33,53,34,4    
IM 151-8 PN/DP CPU0 ms---------0---ET 200M PN HF1642,83,44,36,1    
IM 151-8 PN/DP CPU0 ms---------0---ET 200M PN HF142,74,24,36,9    
CPU 414-2DP0 msCP443-1 Adv (GX20)------0---ET 200M PN HF142,36,33,47,2    
PC277D-RTX0 ms---------0---ET 200M PN HF1642,35,72,35,9    
PC677C-RTX0 ms---------0---ET 200M PN HF1641,65,82,45,6    
1 |  2 |  3 |  4 |  5 |  6 ...527
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Nom de la colonneDescription
CPU Type UC
CPUFW Version firmware CPU
Prg-Load Charge par programme dans OB1
CP Type UC
CPFW Version firmware CP
R-CPU Unité centrale de réception
R-CPUFW Version firmware CPU
R-CP CP de réception
R-CPFW Version firmware CP
Protocol Service de communication
DataLength Taille data [octets]
Num R-Stations Nombre des stations de réception
PG Type PG
HMI Type HMI
Num HMI Stations Nombre de stations HMI
HMI-PrgLoad Étendue projet IHM
Net-Link Branchement secteur
Net-LinkFW Version firmware du raccordement au réseau
NumWLANCells Nombre de clients WLAN
Device Type d’appareil d'Entrée/Sortie
Num devices Nombre de stations de l’appareil d'Entrée/Sortie
IO-Bytes Somme d’octets EA par station
PNIO_SendClock[ms] PN E/S cycle d'émission [ms]
T Rea min [ms] Temps mini de réponse PN via image du processus [ms]
T Rea avg [ms] mps moyen de réponse PN via mémoire image[ms]
T Rea max [ms] Temps maxi de réspons PN via mémoire image[ms]
T Rea Alrm min[ms] Temps mini de réponse PN via alarme process/instructions directes [ms]
T Rea Alrm avg[ms] Temps moyen de réponse PN via alarme process/instructions directes [ms]
T Rea Alrm max[ms] Temps maxi de réponse PN via alarme process/instructions directes [ms]
T ReaSynch min[ms] Temps de réponse PN minimal via l’alarme de synchronisation[ms]
T ReaSynch avg[ms] Temps de réponse PN moyen via l’alarme de synchronisation[ms]
T ReaSynch max]ms] Temps de réponse PN maximal via l’alarme de synchronisation[ms]
TransTime_min[ms] Durée de transmission mini [ms]
TransTime_avg[ms] Durée de transmission moyenne [ms]
TransTime_max[ms] Durée de transmission maxi [ms]
Cycle time min[ms] Durée mini cycle OB1 [ms]
Cycle time avg[ms] Durée moyenne cycle OB1 [ms]
Cycle time max[ms] Durée maxi cycle OB1 [ms]
R-Cycle time min[ms] Durée minimale cycle OB1 (unité centrale de réception) [ms]
R-Cycle time avg[ms] Durée moyenne cycle OB1 (unité centrale de réception) [ms]
R-Cycle time max[ms] Durée maximale cycle OB1 (unité centrale de réception) [ms]
T HMI upd. min [ms] Temps mini de mise à jour [ms] sur panneau IHM
T HMI upd. avg [ms] Temps moyen de mise à jour [ms] sur panneau IHM
T HMI upd. max [ms] Temps maxi de mise à jour [ms] sur panneau IHM
T HMI op. min [ms] Temps mini de commande [ms] sur panneau IHM
T HMI op. avg [ms] Temps moyen de commande [ms] sur panneau IHM
T HMI op. max [ms] Temps maxi de commande [ms] sur panneau IHM
T PPC upd. min [ms] Temps mini de mise à jour [ms] sur PanelPC
T PPC upd. avg. [ms] Temps typique de mise à jour [ms] sur PanelPC
T PPC upd. max [ms] Temps maxi de mise à jour [ms] sur PanelPC
T PPC op. min [ms] Temps mini de commande [ms] sur PanelPC
T PPC op. avg. [ms] Temps moyen de commande [ms] sur PanelPC
T PPC op. max [ms] Temps maxi de commande [ms] sur PanelPC
 
siemens.com Global Website |
© Siemens AG 2002-2024 -
Corporate Information | Privacy Policy | Terms of Use | Digital ID