SIEMENS


Skip over Site Identifier

Healthcare USA

Close Site Id Layer

nouveau

 

about

Version: V7.0
DB: Jun 2009
 

related

Version: V2.0 DB: Apr 2006
Version: V3.0 DB: Sept 2006
Version: V4.0 DB: Jun 2007
Version: V6.0 DB: Jul 2008
Version: V8.1 DB: Jan 2011
Version: V9.0 DB: Jul 2015


Skip over Language Switch

Language switch

  • English
  • Deutsch
  • Français
  • Italiano
  • Español
  • 中文

Skip over Generic Navigation

  • Contact

Skip over Help

Help


Choix de la configuration
Contrôleur IORéseauPériphérie
CPU
nothing selected
 IM 151-8 PN/DP CPU
 CPU 315-2DP(V3)
 CPU 315-2PN/DP(V3)
 CPU 317-2PN/DP(V3)
 CPU 317-2PN/DP
 CPU 319-3PN/DP
 CPU 414-2DP
 CPU 414-3PN/DP
 CPU 416-3PN/DP
 S7-mEC EC31-RTX
 PC477B-RTX
 PC477B-HMI/RTX
 PC677B-RTX
 PC677B-HMI/RTX
CP
nothing selected
 ---
 CP343-1 (EX30)
 CP343-1 Adv (GX30)
 CP443-1 Adv (GX20)
 CP 1616
Charge par programme
nothing selected
 50 ms
 50ms + LARGE
 50ms + ENHANCED
 6 ms
 6ms + LARGE
 6ms + ENHANCED
Charge sur le réseau
nothing selected
 ---
 PG
 TP 177B
Nombre d'appareils de charge de réseau
nothing selected
 0
 1
 4
 7
Volume de configuration des appareils IHM
nothing selected
 ---
 Small
 Large
Branchement secteur
nothing selected
 wired
 SCALANCE W786-2RR
Nombre de clients WLAN
nothing selected
 0
 1
 4
 8
 16
Type
nothing selected
 ET 200M PN
 ET 200S PN HF
 ET 200pro IWLAN
Nombre de stations
nothing selected
 1
 8
 16
 32
 60
Octets ES par station
nothing selected
 4
 16
 30
 32
 
Performances prédéfinies
Temps de réponseTemps de commandeTemps de mise à jour
T Rea min [ms]
Nothing set

must be of type integer
T Rea max [ms]
Nothing set

must be of type integer
T Rea Alrm min[ms]
Nothing set

must be of type integer
T Rea Alrm max[ms]
Nothing set

must be of type integer
T HMI op. min [ms]
Nothing set

must be of type integer
T HMI op. max [ms]
Nothing set

must be of type integer
T PPC op. min [ms]
Nothing set

must be of type integer
T PPC op. max [ms]
Nothing set

must be of type integer
T HMI upd. min [ms]
Nothing set

must be of type integer
T HMI upd. max [ms]
Nothing set

must be of type integer
T PPC upd. min [ms]
Nothing set

must be of type integer
T PPC upd. max [ms]
Nothing set

must be of type integer
 
Configuration choisie
Charge par programme:nothing selected
Nombre d'appareils de charge de réseau:nothing selected
Volume de configuration des appareils IHM:nothing selected
Nombre de clients WLAN:nothing selected
Nombre de stations:nothing selected
Octets ES par station:nothing selected
 

Résultats: 9926 de 9926      Télécharger résultats (*.csv)

Montrer colonnes

CPUPrg-LoadCPNet-LoadNum Net-LoadHMI-PrgLoadNet-LinkNumWLANCellsDeviceNum devicesIO-BytesT Rea min [ms]T Rea max [ms]T Rea Alrm min[ms]T Rea Alrm max[ms]
S7-mEC EC31-RTX6 ms---TP 177B4Largewired0ET 200M PN6044,710,31,95,2
CPU 416-3PN/DP6 ms------0---wired0ET 200M PN147,114,93,37,2
CPU 416-3PN/DP6 ms---TP 177B7Smallwired0ET 200M PN147,215,12,97,6
CPU 414-3PN/DP6 ms---TP 177B1Smallwired0ET 200M PN147,114,83,16,7
CPU 414-3PN/DP6 ms---TP 177B7Smallwired0ET 200M PN147,214,33,57,2
CPU 414-3PN/DP6 ms------0---wired0ET 200M PN147,214,12,86,9
CPU 414-3PN/DP6 ms---TP 177B4Smallwired0ET 200M PN146,814,72,96,7
CPU 416-3PN/DP6 ms---TP 177B1Largewired0ET 200M PN146,615,12,96,7
CPU 416-3PN/DP6 ms---TP 177B1Smallwired0ET 200M PN14714,83,57,4
CPU 416-3PN/DP6 ms---PG1---wired0ET 200M PN146,715,33,17,8
CPU 414-3PN/DP6 ms---PG1---wired0ET 200M PN147,115,43,28,3
CPU 416-3PN/DP6 ms---TP 177B1Smallwired0ET 200M PN164714,72,86,8
CPU 416-3PN/DP6 ms---TP 177B1Largewired0ET 200M PN1647,215,22,86,9
CPU 414-3PN/DP6 ms---TP 177B4Smallwired0ET 200M PN1647,214,73,37
CPU 414-3PN/DP6 ms---TP 177B1Largewired0ET 200M PN1647,215,23,36,6
CPU 414-3PN/DP6 ms------0---wired0ET 200M PN1647,414,53,37,3
CPU 416-3PN/DP6 ms---TP 177B7Smallwired0ET 200M PN1647,1152,77,1
CPU 416-3PN/DP6 ms---TP 177B4Smallwired0ET 200M PN147,114,937,8
CPU 416-3PN/DP6 ms---TP 177B7Largewired0ET 200M PN147,215,82,97,1
CPU 414-3PN/DP6 ms---TP 177B4Largewired0ET 200M PN147,115,13,17,4
1 |  2 |  3 |  4 |  5 |  6 ...497
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Nom de la colonneDescription
CPU Type UC
CPUFW Version firmware CPU
Prg-Load Charge par programme dans OB1
CP Type UC
CPFW Version firmware CP
Net-Load Type de la charge réseau
Num Net-Load Nombre charges réseau
HMI-PrgLoad Étendue projet IHM
Net-Link Branchement secteur
Net-LinkFW Version firmware du raccordement au réseau
NumWLANCells Nombre de clients WLAN
Device Type d’appareil d'Entrée/Sortie
Num devices Nombre de stations de l’appareil d'Entrée/Sortie
IO-Bytes Octets ES par station
IO-Bytes PI Total octets ES via image du processus
IO-Bytes Alrm Total octets ES via alarme process / instructions directes
T Rea min [ms] Temps mini de réponse PN via image du processus [ms]
T Rea avg [ms] mps moyen de réponse PN via mémoire image[ms]
T Rea max [ms] Temps maxi de réspons PN via mémoire image[ms]
T Rea Alrm min[ms] Temps mini de réponse PN via alarme process/instructions directes [ms]
T Rea Alrm avg[ms] Temps moyen de réponse PN via alarme process/instructions directes [ms]
T Rea Alrm max[ms] Temps maxi de réponse PN via alarme process/instructions directes [ms]
Cycle time min[ms] Durée mini cycle OB1 [ms]
Cycle time avg[ms] Durée moyenne cycle OB1 [ms]
Cycle time max[ms] Durée maxi cycle OB1 [ms]
PNIO_SendClock[ms] PN E/S cycle d'émission [ms]
T HMI upd. min [ms] Temps mini de mise à jour [ms] sur panneau IHM
T HMI upd. avg [ms] Temps moyen de mise à jour [ms] sur panneau IHM
T HMI upd. max [ms] Temps maxi de mise à jour [ms] sur panneau IHM
T HMI op. min [ms] Temps mini de commande [ms] sur panneau IHM
T HMI op. avg [ms] Temps moyen de commande [ms] sur panneau IHM
T HMI op. max [ms] Temps maxi de commande [ms] sur panneau IHM
T PPC upd. min [ms] Temps mini de mise à jour [ms] sur PanelPC
T PPC upd. avg. [ms] Temps typique de mise à jour [ms] sur PanelPC
T PPC upd. max [ms] Temps maxi de mise à jour [ms] sur PanelPC
T PPC op. min [ms] Temps mini de commande [ms] sur PanelPC
T PPC op. avg. [ms] Temps moyen de commande [ms] sur PanelPC
T PPC op. max [ms] Temps maxi de commande [ms] sur PanelPC
 
siemens.com Global Website |
© Siemens AG 2002-2024 -
Corporate Information | Privacy Policy | Terms of Use | Digital ID