SIEMENS


Skip over Site Identifier

Healthcare USA

Close Site Id Layer

nouveau

 

about

Version: V4.0
DB: Feb 2009
 

related

Version: V2.0 DB: V2.0
Version: V3.0 DB: Jul 2008
Version: V5.0 DB: Jul 2012


Skip over Language Switch

Language switch

  • English
  • Deutsch
  • Français
  • Italiano
  • Español
  • 中文

Skip over Generic Navigation

  • Contact

Skip over Help

Help


Choix de la configuration
Maitre-DPRéseauEsclaves-DP
CPU
nothing selected
 CPU 315-2DP
 CPU 317-2DP
 CPU 317-2PN/DP
 CPU 319-3PN/DP
 CPU 414-2DP
 CPU 414-3PN/DP
 CPU 416-2DP
 CPU 416-3PN/DP
 CPU 412-3H (red.)
 CPU 412-3H(solo)
 CPU 417-4H (red.)
 CPU 417-4H (solo)
 S7-mEC EC31-RTX
 PC477B-RTX
 PC477B-HMI/RTX
 PC677B-RTX
 PC677B-HMI/RTX
CP
nothing selected
 ---
 CP5603
 CP342-5
 CP443-5 Ext
 CP443-5 Ext Red
Charge par programme
nothing selected
 10 ms
 50 ms
 10ms + LARGE
 10ms + ENHANCED
 50ms + LARGE
 50ms + ENHANCED
Charge sur le réseau
nothing selected
 ---
 PG
 TP 177B
Nombre d'appareils de charge de réseau
nothing selected
 0
 1
 4
 7
Volume de configuration des appareils IHM
nothing selected
 ---
 Small
 Large
Baudrate
nothing selected
 1,5 MBaud
 12 MBaud
Type d'esclave-DP
nothing selected
 ET 200M DP HF
 ET 200S DP HF
 ET200M Red. Bundle
Nombre del Y-Links
nothing selected
 0
 1
 2
 4
Nombre de stations
nothing selected
 1
 8
 16
 32
 60
Octets ES par station
nothing selected
 4
 16
 30
 32
 
Performances prédéfinies
Temps de réponseTemps de commandeTemps de mise à jour
T Rea min [ms]
Nothing set

must be of type integer
T Rea max [ms]
Nothing set

must be of type integer
T Rea Alrm min[ms]
Nothing set

must be of type integer
T Rea Alrm max[ms]
Nothing set

must be of type integer
T HMI op. min [ms]
Nothing set

must be of type integer
T HMI op. max [ms]
Nothing set

must be of type integer
T PPC op. min [ms]
Nothing set

must be of type integer
T PPC op. max [ms]
Nothing set

must be of type integer
T HMI upd. min [ms]
Nothing set

must be of type integer
T HMI upd. max [ms]
Nothing set

must be of type integer
T PPC upd. min [ms]
Nothing set

must be of type integer
T PPC upd. max [ms]
Nothing set

must be of type integer
 
Configuration choisie
Charge par programme:nothing selected
Nombre d'appareils de charge de réseau:nothing selected
Volume de configuration des appareils IHM:nothing selected
Nombre del Y-Links:nothing selected
Nombre de stations:nothing selected
Octets ES par station:nothing selected
 

Résultats: 7744 de 7744      Télécharger résultats (*.csv)

Montrer colonnes

CPUPrg-LoadCPDP BaudrateNet-LoadNum Net-LoadHMI-PrgLoadSlaveNum slavesIO-BytesT Rea avg [ms]T Rea Alrm avg[ms]
CPU 412-3H(solo)10 msCP443-5 Ext Red12 MBaud---0---ET200M Red. Bundle13213,46,5
CPU 412-3H(solo)10 msCP443-5 Ext Red12 MBaud---0---ET200M Red. Bundle11613,55,6
CPU 412-3H(solo)10 ms---12 MBaud---0---ET200M Red. Bundle11613,66,5
CPU 412-3H(solo)10 ms---12 MBaud---0---ET200M Red. Bundle1413,86
CPU 412-3H(solo)10 msCP443-5 Ext Red1,5 MBaud---0---ET200M Red. Bundle1413,96,6
CPU 412-3H(solo)10 msCP443-5 Ext Red12 MBaud---0---ET200M Red. Bundle14145,2
CPU 412-3H(solo)10 ms---12 MBaud---0---ET200M Red. Bundle132147,3
CPU 414-3PN/DP10 ms---12 MBaud---0---ET 200M DP HF1414,11,8
CPU 416-2DP10 ms---12 MBaud---0---ET 200M DP HF11614,11,8
CPU 416-2DP10 ms---12 MBaudTP 177B1SmallET 200M DP HF1414,11,8
CPU 416-2DP10 ms---12 MBaudTP 177B4SmallET 200M DP HF1414,11,8
CPU 416-2DP10 ms---12 MBaudTP 177B1LargeET 200M DP HF1414,11,8
CPU 416-2DP10 ms---12 MBaudTP 177B1SmallET 200M DP HF11614,11,9
CPU 412-3H(solo)10 ms---1,5 MBaud---0---ET200M Red. Bundle1414,16,9
CPU 416-2DP10 ms---12 MBaud---0---ET 200M DP HF1414,21,7
CPU 416-2DP10 ms---12 MBaudTP 177B4LargeET 200M DP HF1414,21,8
CPU 416-2DP10 ms---12 MBaudTP 177B1LargeET 200M DP HF11614,21,9
CPU 414-3PN/DP10 ms---12 MBaudTP 177B1LargeET 200M DP HF1414,21,9
CPU 416-2DP10 ms---12 MBaudPG1---ET 200M DP HF1414,21,9
CPU 414-3PN/DP10 ms---12 MBaud---0---ET 200M DP HF11614,22
1 |  2 |  3 |  4 |  5 |  6 ...388
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Nom de la colonneDescription
CPU Type UC
CPUFW Version firmware CPU
Prg-Load Charge par programme dans OB1
CP Type UC
CPFW Version firmware CP
DP Baudrate Bauds sur PROFIBUS DP
Net-Load Type de la charge réseau
Num Net-Load Nombre charges réseau
HMI-PrgLoad Étendue projet IHM
Slave Type esclave DP
Num Y-Links Nombre del Y-Links
Num slaves Nombre stations esclave DP
IO-Bytes Octets ES par station
IO-Bytes PI Total octets ES via image du processus
IO-Bytes Alrm Total octets ES via alarme process / instructions directes
T Rea min [ms] Temps mini de réponse DP [ms] via image du processus
T Rea avg [ms] Temps moyen de réponse DP [ms] via image du processus
T Rea max [ms] Temps maxi de réponse DP [ms] via image du processus
T Rea Alrm min[ms] Temps mini de réponse DP [ms] via alarme process/instructions directes
T Rea Alrm avg[ms] Temps moyen de réponse DP [ms] via alarme process/instructions directes
T Rea Alrm max[ms] Temps maxi de réponse DP [ms] via alarme process/instructions directes
Cycle time min[ms] Durée mini cycle OB1 [ms]
Cycle time avg[ms] Durée moyenne cycle OB1 [ms]
Cycle time max[ms] Durée maxi cycle OB1 [ms]
T HMI upd. min [ms] Temps mini de mise à jour [ms] sur panneau IHM
T HMI upd. avg [ms] Temps moyen de mise à jour [ms] sur panneau IHM
T HMI upd. max [ms] Temps maxi de mise à jour [ms] sur panneau IHM
T HMI op. min [ms] Temps mini de commande [ms] sur panneau IHM
T HMI op. avg [ms] Temps moyen de commande [ms] sur panneau IHM
T HMI op. max [ms] Temps maxi de commande [ms] sur panneau IHM
T PPC upd. min [ms] Temps mini de mise à jour [ms] sur PanelPC
T PPC upd. avg. [ms] Temps typique de mise à jour [ms] sur PanelPC
T PPC upd. max [ms] Temps maxi de mise à jour [ms] sur PanelPC
T PPC op. min [ms] Temps mini de commande [ms] sur PanelPC
T PPC op. avg. [ms] Temps moyen de commande [ms] sur PanelPC
T PPC op. max [ms] Temps maxi de commande [ms] sur PanelPC
 
siemens.com Global Website |
© Siemens AG 2002-2024 -
Corporate Information | Privacy Policy | Terms of Use | Digital ID