Choice of configuration
Statione S7Server OPCClient OPC
CPU
nothing selected
 CPU 1518-4
 CPU 1516-3
 CPU 1511-1
 CPU 1212C
 CPU 1515SP PC
 CPU 1507S (IPC 427D)
CP
nothing selected
 ---
 CP 1543-1
 CM 1542-1
 CP 1243-1
Carico da programma
nothing selected
 1 ms
 5 ms
 10 ms
 50 ms
Lunghezza dati [byte]
nothing selected
 100
 1000
 10000
 100000
Numero di stazioni
nothing selected
 1
 4
 16
DB type
nothing selected
 optimized DB
 standard DB
Distribution of variables
nothing selected
 continuous byte array
 distributed variables
Tipo PC
SIMATIC IPC 547E
Tipo server OPC
SIMATIC NET OPC UA
OPC cycle time
nothing selected
 50 ms
 100 ms
OPC Client Location
nothing selected
 Local
 Remote (LAN)
Servizio OPC
nothing selected
 Registered Read
 Registered Write
 Monitoring via UA-subscription
 Monitoring via CPU-subscription
 
Performance Requirements
Tempi di trasferimento
TransTime_min[ms]
Nothing set

must be of type integer
TransTime_avg[ms]
Nothing set

must be of type integer
TransTime_max[ms]
Nothing set

must be of type integer
 
Chosen topology
Carico da programma:nothing selected
Numero stazioni S7:nothing selected
bytes per S7 station:nothing selected
SIMATIC IPC 547E
not supportednothing selected
 

Results: 7272 of 7272      Download results (*.csv)

Show columns

CPUPrg-LoadCPNum S7-stationsNum ItemsOPC-ClientLocOPC-ServiceTransTime_min[ms]TransTime_avg[ms]TransTime_max[ms]
CPU 1518-41 ms---1100LocalRegistered Write1,21,33,3
CPU 1518-410 ms---1100LocalRegistered Read1,61,64,3
CPU 1518-41 ms---1100LocalRegistered Read1,51,64,4
CPU 1518-410 ms---1100LocalRegistered Write1,61,64,3
CPU 1518-410 ms---1100LocalRegistered Read1,61,64,4
CPU 1518-41 ms---1100LocalRegistered Read1,51,64,6
CPU 1518-45 ms---4100LocalRegistered Read1,61,64,5
CPU 1518-410 ms---1100LocalRegistered Write1,51,64,7
CPU 1518-41 ms---1100LocalRegistered Read1,61,64,5
CPU 1518-45 ms---1100LocalRegistered Read1,51,64,8
CPU 1518-410 ms---1100LocalRegistered Write1,61,64,7
CPU 1518-45 ms---1100LocalRegistered Write1,51,64,8
CPU 1518-410 ms---11000LocalRegistered Write1,61,63,8
CPU 1518-45 ms---41000LocalRegistered Read1,61,63,2
CPU 1518-45 ms---11000LocalRegistered Write1,61,64,7
CPU 1518-410 ms---11000LocalRegistered Write1,61,64,9
CPU 1518-410 ms---41000LocalRegistered Read1,61,64,1
CPU 1518-410 ms---11000LocalRegistered Write1,61,63,2
CPU 1518-410 ms---11000LocalRegistered Write1,61,64,8
CPU 1518-45 ms---41000LocalRegistered Read1,61,63,9
1 |  2 |  3 |  4 |  5 |  6 ...364
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Name of columnDescription
CPU CPU type
CPUFW Firmware version CPU
Prg-Load Load due to program in OB1
CP CP type
CPFW Firmware version CP
Num S7-stations Number of SIMATIC stations
Num Items Number of items (bytes) per S7 station
Server PC OPC server PC type
DB Type Data block type (standard/optimized)
OPC-Server Cycle OPC cycle time
Var. distribution Distribution of variables
OPC-ServerType OPC server type
OPC-ClientLoc OPC client location
OPC-Service OPC service
TransTime_min[ms] minimum transmission time [ms]
TransTime_Q25[ms] 25% quartile transmission time[ms]
TransTime_avg[ms] average transmission time [ms]
TransTime_Q75[ms] 75% quartile transmission time[ms]
TransTime_max[ms] maximum transmission time [ms]
Cycle time min[ms] Minimum OB1 cycle time[ms]
Cycle time avg[ms] Average OB1 cycle time[ms]
Cycle time max[ms] Maximum OB1 cycle time[ms]
 