Choice of configuration
DP masterNetDP slaves
CPU
nothing selected
 CPU 416-3PN/DP
 CPU 1215C
 CPU 315-2DP (OCM Prio)
 CPU 317-2PN/DP (OCM Prio)
 CPU 319-3PN/DP (OCM Prio)
 CPU 414-2DP
 CPU 414-3PN/DP
 PC477C-RTX
 PC477C-HMI/RTX
 PC677C-RTX
 PC677C-HMI/RTX
CP
nothing selected
 ---
 CM1243-5
 CP 342-5
 CP443-5 Ext
Load due to program
nothing selected
 0 ms
 6 ms
 50 ms
 6ms + LARGE
 6ms + ENHANCED
 50ms + LARGE
 50ms + ENHANCED
Baudrate
nothing selected
 1,5 MBaud
 12 MBaud
Type of DP slave
nothing selected
 ET 200S DP HF
 ET 200M DP HF
Number of stations
nothing selected
 1
 8
 16
 32
 60
IO bytes per station
nothing selected
 4
 16
 30
 32
Load on net
EngineeringHMI
PG
nothing selected
 ---
 PG
HMI
nothing selected
 ---
 TP700 Comfort
Number of stations
nothing selected
 0
 1
 4
Scale of HMI programs
nothing selected
 ---
 Small
 Large
 
Performance Requirements
Reaction timesOperating timesUpdate times
T Rea avg [ms]
Nothing set

must be of type integer
T Rea Alrm avg[ms]
Nothing set

must be of type integer
T HMI op. avg [ms]
Nothing set

must be of type integer
T PPC op. avg. [ms]
Nothing set

must be of type integer
T HMI upd. avg [ms]
Nothing set

must be of type integer
T PPC upd. avg. [ms]
Nothing set

must be of type integer
 
Chosen topology
Load due to program:nothing selected
Number of stations:nothing selected
IO bytes per station:nothing selected
Number of HMI stations:nothing selected
Scale of HMI programs:nothing selected
 

Results: 4109 of 4109      Download results (*.csv)

Show columns

CPUPrg-LoadCPDP BaudratePGHMINum HMI StationsHMI-PrgLoadSlaveNum slavesIO-BytesT Rea avg [ms]T Rea Alrm avg[ms]
CPU 319-3PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF11612,2
CPU 416-3PN/DP0 ms---12 MBaud------0---ET 200M DP HF1161,12,1
CPU 416-3PN/DP0 msCP443-5 Ext12 MBaud------0---ET 200M DP HF1161,13,7
CPU 414-3PN/DP0 ms---12 MBaud------0---ET 200M DP HF1161,22,1
CPU 414-3PN/DP0 ms---12 MBaudPG---0---ET 200M DP HF1161,22,2
CPU 317-2PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF1161,32
CPU 416-3PN/DP0 ms---12 MBaud------0---ET 200M DP HF1321,32,3
CPU 319-3PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF1321,32,3
CPU 414-3PN/DP0 ms---12 MBaudPG---0---ET 200M DP HF1321,42,3
CPU 414-3PN/DP0 ms---12 MBaud------0---ET 200M DP HF1321,42,3
CPU 317-2PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF1641,42,3
CPU 319-3PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF1641,42,5
CPU 416-3PN/DP0 msCP443-5 Ext12 MBaud------0---ET 200M DP HF1321,44
CPU 317-2PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF1321,52,3
CPU 319-3PN/DP (OCM Prio)0 ms---1,5 MBaud------0---ET 200M DP HF1161,53,2
CPU 416-3PN/DP0 ms---1,5 MBaud------0---ET 200M DP HF1161,63
CPU 315-2DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF1161,72,6
CPU 319-3PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF16161,72,8
CPU 317-2PN/DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF16161,82,6
CPU 315-2DP (OCM Prio)0 ms---12 MBaud------0---ET 200M DP HF1321,92,9
1 |  2 |  3 |  4 |  5 |  6 ...206
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Name of columnDescription
CPU CPU type
CPUFW Firmware version CPU
Prg-Load Load due to program in OB1
CP CP type
CPFW Firmware version CP
DP Baudrate Baudrate on PROFIBUS DP
PG PG type
HMI HMI type
Num HMI Stations Number of HMI stations
HMI-PrgLoad Scale of HMI programs
Slave DP slave type
Num slaves Number of DP slave stations
IO-Bytes Total of IO bytes per station
T Rea min [ms] Minimum DP reaction time via process image[ms]
T Rea avg [ms] Average DP reaction time via process image[ms]
T Rea max [ms] Maximum DP reaction time via process image[ms]
T Rea Alrm min[ms] Minimum DP reaction time via process alarm/direct commands[ms]
T Rea Alrm avg[ms] Average DP reaction time via process alarm/direct commands[ms]
T Rea Alrm max[ms] Maximum DP reaction time via process alarm/direct commands[ms]
Cycle time min[ms] Minimum OB1 cycle time[ms]
Cycle time avg[ms] Average OB1 cycle time[ms]
Cycle time max[ms] Maximum OB1 cycle time[ms]
T HMI upd. min [ms] Minimum update time on the HMI panel [ms]
T HMI upd. avg [ms] Average update time on the HMI panel [ms]
T HMI upd. max [ms] Maximum update time on the HMI panel [ms]
T HMI op. min [ms] Minimum operating time on the HMI panel [ms]
T HMI op. avg [ms] Average operating time on the HMI panel [ms]
T HMI op. max [ms] Maximum operating time on the HMI panel [ms]
T PPC upd. min [ms] Minimum update time on the PanelPC [ms]
T PPC upd. avg. [ms] Typical update time on the PanelPC [ms]
T PPC upd. max [ms] Maximum update time on the PanelPC [ms]
T PPC op. min [ms] Minimum operating time on the PanelPC [ms]
T PPC op. avg. [ms] Average operating time on the PanelPC [ms]
T PPC op. max [ms] Maximum operating time on the PanelPC [ms]
 