SIEMENS


Skip over Site Identifier

Healthcare USA

Close Site Id Layer

nuevo

 

about

Version: V6.0
DB: Jul 2008
 

related

Version: V7.0 DB: Jun 2009
Version: V2.0 DB: Apr 2006
Version: V3.0 DB: Sept 2006
Version: V4.0 DB: Jun 2007
Version: V8.1 DB: Jan 2011
Version: V9.0 DB: Jul 2015


Skip over Language Switch

Language switch

  • English
  • Deutsch
  • Français
  • Italiano
  • Español
  • 中文

Skip over Generic Navigation

  • Contact

Skip over Help

Help


Selección de la configuración
Controlador IORedPeriferia
CPU
nothing selected
 CPU 315-2DP
 CPU 317-2PN/DP
 CPU 319-3PN/DP
 CPU 414-2DP
 CPU 414-3PN/DP
 CPU 416-3PN/DP
 PC477B-RTX
 PC477B-HMI/RTX
 Sinumerik 840D SL NCU 720.2 PN
 PC677B-RTX
 PC677B-HMI/RTX
CP
nothing selected
 ---
 CP 443-1 Adv (EX41)
 CP 343-1 (EX30)
 CP 443-1 (EX20)
 CP 1616
Carga por programa
nothing selected
 10 ms
 50 ms
 150 ms
 10ms + LARGE
 10ms + ENHANCED
 50ms + LARGE
 50ms + ENHANCED
Carga en la red
nothing selected
 ---
 PG
 TP 177B
Cantidad de equipos de carga de red
nothing selected
 0
 1
 4
 7
Escala de proyección de los equipos HMI
nothing selected
 ---
 Small
 Large
Tipo de conexión
nothing selected
 wired
 SCALANCE W788-1RR
Número de clientes WLAN
nothing selected
 0
 1
 16
Tipo
nothing selected
 ET 200S PN
 ET 200M PN
Número de estaciones
nothing selected
 1
 16
 32
 60
IO bytes per estacíon
nothing selected
 2
 16
 30
 32
 
Parámetros especificados
Tiempos de reacciónTiempos de servicioTiempos de actualización
T Rea min [ms]
Nothing set

must be of type integer
T Rea max [ms]
Nothing set

must be of type integer
T Rea Alrm min[ms]
Nothing set

must be of type integer
T Rea Alrm max[ms]
Nothing set

must be of type integer
T HMI op. min [ms]
Nothing set

must be of type integer
T HMI op. max [ms]
Nothing set

must be of type integer
T PPC op. min [ms]
Nothing set

must be of type integer
T PPC op. max [ms]
Nothing set

must be of type integer
T HMI upd. min [ms]
Nothing set

must be of type integer
T HMI upd. max [ms]
Nothing set

must be of type integer
T PPC upd. min [ms]
Nothing set

must be of type integer
T PPC upd. max [ms]
Nothing set

must be of type integer
 
Topologia seleccionada
Carga por el programa:nothing selected
Cantidad de equipos de carga de red:nothing selected
Escala de proyección de los equipos HMI:nothing selected
Número de clientes WLAN:nothing selected
Número de estaciones:nothing selected
IO bytes per estatión:nothing selected
 

Resultados: 5764 de 5764      Descargar resultados (*.csv)

Mostrar columnas

CPUPrg-LoadCPNet-LoadNum Net-LoadHMI-PrgLoadNet-LinkNumWLANCellsDeviceNum devicesIO-BytesT Rea min [ms]T Rea max [ms]
CPU 416-3PN/DP10 ms---TP 177B1Smallwired0ET 200M PN1212,823,5
CPU 414-3PN/DP10 ms---TP 177B1Smallwired0ET 200M PN1212,924,3
CPU 414-3PN/DP10 ms---TP 177B7Smallwired0ET 200M PN121324
CPU 416-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN1212,924,1
CPU 416-3PN/DP10 ms---TP 177B7Smallwired0ET 200M PN121324,2
CPU 414-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN1213,424,4
CPU 416-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN1213,323,7
CPU 416-3PN/DP10 ms---TP 177B4Largewired0ET 200M PN1213,324,5
CPU 414-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN16213,224,3
CPU 416-3PN/DP10 ms---TP 177B1Smallwired0ET 200M PN1621324,2
CPU 414-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN1213,124,8
CPU 414-3PN/DP10 ms------0---wired0ET 200M PN1213,423,6
CPU 416-3PN/DP10 ms------0---wired0ET 200M PN1213,223,8
CPU 416-3PN/DP10 ms------0---wired0ET 200M PN1621324
CPU 414-3PN/DP10 ms------0---wired0ET 200M PN16213,324,6
CPU 416-3PN/DP10 ms---PG1---wired0ET 200M PN1213,324,4
CPU 414-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN16213,224,2
CPU 414-3PN/DP10 ms---TP 177B7Smallwired0ET 200M PN1621324,3
CPU 416-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN16213,126
CPU 416-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN1621324,4
1 |  2 |  3 |  4 |  5 |  6 ...289
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Nombre de la columnaDescripción
CPU Tipo de UC
CPUFW Versión de firmware CPU
Prg-Load Carga por el programa en el OB1
CP Tipo de CP
CPFW Versión de firmware CP
Net-Load Tipo de la carga de red
Num Net-Load Cantidad cargas de red
HMI-PrgLoad Escala del proyecto de equipos IHM
Net-Link Tipo de conexión
Net-LinkFW Versión de firmware Conexión de red
NumWLANCells Número de clientes WLAN
Device Tipo de dispositivo IO
Num devices Número de dispositivos IO Estaciones
IO-Bytes IO bytes per station
IO-Bytes PI Total bytes ES vía imagen de proceso
T Rea min [ms] Tiempo mínimo de reacción DN [ms] vía imagen de proceso
T Rea avg [ms] Tiempo medio de reacción PN [ms] vía imagen de proceso
T Rea max [ms] Tiempo máximo de reacción PN[ms] vía imagen de proceso
Cycle time min[ms] Tiempo mínimo de ciclo OB1 [ms]
Cycle time avg[ms] Tiempo medio de ciclo OB1 [ms]
Cycle time max[ms] Tiempo máximo de ciclo OB1 [ms]
PNIO_SendClock[ms] PN IO ciclo de envío [ms]
T HMI upd. min [ms] Tiempo mínimo de actualización en panel IHM [ms]
T HMI upd. avg [ms] Tiempo medio de actualización en panel IHM [ms]
T HMI upd. max [ms] Tiempo máximo de actualización en panel IHM [ms]
T HMI op. min [ms] Tiempo mínimo de servicio en panel IHM [ms]
T HMI op. avg [ms] Tiempo medio de servicio en panel IHM [ms]
T HMI op. max [ms] Tiempo máximo de servicio en panel IHM [ms]
T PPC upd. min [ms] Tiempo mínimo de actualización en PanelPC [ms]
T PPC upd. avg. [ms] Tiempo típico de actualización en PanelPC [ms]
T PPC upd. max [ms] Tiempo máximo de actualización en PanelPC [ms]
T PPC op. min [ms] Tiempo mínimo de servicio en PanelPC [ms]
T PPC op. avg. [ms] Tiempo medio de servicio en PanelPC [ms]
T PPC op. max [ms] Tiempo máximo de servicio en PanelPC [ms]
 
siemens.com Global Website |
© Siemens AG 2002-2024 -
Corporate Information | Privacy Policy | Terms of Use | Digital ID