Help


Choice of configuration
S7 - stationOPC - serverOPC - client
CPU
nothing selected
 CPU 315-2DP
 CPU 315-2PN/DP(OCM Prio)
 CPU 315-2PN/DP
 CPU 319-3PN/DP
 CPU 319-3PN/DP (OCM Prio)
 CPU 414-3PN/DP
CP
nothing selected
 ---
 CP 443-1 (EX20)
 CP 343-1 (EX30)
Load due to program
nothing selected
 0 ms
 100 ms
 6 ms
Data length [Bytes]
nothing selected
 100
 1000
 10000
Number of stations
nothing selected
 1
 4
 8
 16
PC - type
IPC 547C
OPC - PLC protocol
S7-protocol
OPC - server type
nothing selected
 DA (D)COM
 DA UA
OPC client location
nothing selected
 Local
 Remote (LAN)
OPC - service
nothing selected
 Monitoring Variables
 Read
 Write
 Block Send (PC -> PLC)
 Block Send (PLC -> PC)
 
Performance Requirements
Transfer times
TransTime_avg[ms]
Nothing set

must be of type integer
 
Chosen topology
Load due to program:nothing selected
Number of S7 stations:nothing selected
bytes per S7 station:nothing selected
OPC - Server Typ:nothing selected
IPC 547C (OPC-Server)
OPC Client Location:nothing selected
 

Results: 2652 of 2652      Download results (*.csv)

Show columns

CPUPrg-LoadCPNum S7-stationsNum ItemsOPC-ServerTypeOPC-ClientLocOPC-ServiceTransTime_avg[ms]
CPU 414-3PN/DP100 ms---1100DA UALocalWrite3,6
CPU 414-3PN/DP6 ms---1100DA UALocalWrite3,6
CPU 414-3PN/DP6 ms---1100DA UALocalRead3,8
CPU 414-3PN/DP100 ms---1100DA UALocalRead3,8
CPU 414-3PN/DP6 msCP 443-1 (EX20)8100DA (D)COMRemote (LAN)Block Send (PC -> PLC)3,9
CPU 414-3PN/DP6 ms---1100DA (D)COMLocalWrite4,1
CPU 414-3PN/DP6 ms---1100DA (D)COMLocalRead4,2
CPU 414-3PN/DP100 ms---1100DA (D)COMLocalWrite4,2
CPU 414-3PN/DP100 ms---1100DA (D)COMLocalRead4,3
CPU 414-3PN/DP100 ms---4100DA (D)COMLocalRead4,3
CPU 414-3PN/DP6 ms---4100DA (D)COMLocalRead4,3
CPU 414-3PN/DP6 ms---4100DA (D)COMLocalWrite4,3
CPU 414-3PN/DP100 ms---4100DA (D)COMLocalWrite4,4
CPU 414-3PN/DP100 ms---1100DA UARemote (LAN)Write4,4
CPU 414-3PN/DP6 ms---1100DA UARemote (LAN)Write4,5
CPU 319-3PN/DP (OCM Prio)100 ms---1100DA UALocalRead4,6
CPU 319-3PN/DP (OCM Prio)100 ms---1100DA UALocalWrite4,6
CPU 414-3PN/DP6 ms---1100DA UARemote (LAN)Read4,8
CPU 414-3PN/DP100 ms---1100DA UARemote (LAN)Read4,8
CPU 414-3PN/DP100 ms---1100DA (D)COMRemote (LAN)Write4,8
1 |  2 |  3 |  4 |  5 |  6 ...133
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Name of columnDescription
CPU CPU type
CPUFW Firmware version CPU
Prg-Load Load due to program in OB1
CP CP type
CPFW Firmware version CP
Num S7-stations Number of SIMATIC stations
Num Items Number of items (bytes) per S7 station
Server PC OPC server PC type
OPC-PLC prot OPC protocol server type to PLC
OPC-ServerType OPC server type
OPC-ClientLoc OPC client location
OPC-Service OPC service
TransTime_min[ms] minimum transmission time [ms]
TransTime_Q25[ms] 25% quartile transmission time[ms]
TransTime_avg[ms] average transmission time [ms]
TransTime_Q75[ms] 75% quartile transmission time[ms]
TransTime_max[ms] maximum transmission time [ms]
Cycle time min[ms] Minimum OB1 cycle time[ms]
Cycle time avg[ms] Average OB1 cycle time[ms]
Cycle time max[ms] Maximum OB1 cycle time[ms]
 