SIEMENS


Skip over Site Identifier

Healthcare USA

Close Site Id Layer

new

 

about

Version: V3.0
DB: Jul 2008
 

related

Version: V4.0 DB: Feb 2009
Version: V2.0 DB: V2.0
Version: V5.0 DB: Jul 2012


Skip over Language Switch

Language switch

  • English
  • Deutsch
  • Français
  • Italiano
  • Español
  • 中文

Skip over Generic Navigation

  • Contact

Skip over Help

Help


Choice of configuration
DP masterNetDP slaves
CPU
nothing selected
 CPU 315-2DP
 CPU 317-2DP
 CPU 317-2PN/DP
 CPU 319-3PN/DP
 CPU 414-2DP
 CPU 414-3PN/DP
 CPU 416-2DP
 CPU 416-3PN/DP
 PC627 (WinAC RTX 2005)
 PC477B-RTX
 PC477B-HMI/RTX
 PC677B-RTX
 PC677B-HMI/RTX
CP
nothing selected
 ---
 CP 443-5 Ext
 CP 342-5
Load due to program
nothing selected
 10 ms
 50 ms
 10ms + LARGE
 10ms + ENHANCED
 50ms + LARGE
 50ms + ENHANCED
Load on net
nothing selected
 ---
 PG
 TP 177B
Number of netload devices
nothing selected
 0
 1
 7
 10
Scale of HMI programs
nothing selected
 ---
 Small
 Large
Baudrate
nothing selected
 1,5 MBaud
 12 MBaud
Type of DP slave
nothing selected
 ET 200M DP
 ET 200S
Number of stations
nothing selected
 1
 16
 32
 60
IO bytes per station
nothing selected
 2
 16
 30
 32
 
Performance Requirements
Reaction timesOperating timesUpdate times
T Rea min [ms]
Nothing set

must be of type integer
T Rea max [ms]
Nothing set

must be of type integer
T HMI op. min [ms]
Nothing set

must be of type integer
T HMI op. max [ms]
Nothing set

must be of type integer
T PPC op. min [ms]
Nothing set

must be of type integer
T PPC op. max [ms]
Nothing set

must be of type integer
T HMI upd. min [ms]
Nothing set

must be of type integer
T HMI upd. max [ms]
Nothing set

must be of type integer
T PPC upd. min [ms]
Nothing set

must be of type integer
T PPC upd. max [ms]
Nothing set

must be of type integer
 
Chosen topology
Load due to program:nothing selected
Number of netload devices:nothing selected
Scale of HMI programs:nothing selected
Number of stations:nothing selected
IO bytes per station:nothing selected
 

Results: 5984 of 5984      Download results (*.csv)

Show columns

CPUPrg-LoadCPNet-LoadHMI-PrgLoadNum Net-LoadDP BaudrateSlaveNum slavesIO-BytesT Rea min [ms]T Rea max [ms]
CPU 414-3PN/DP10 ms---PG---112 MBaudET 200M DP1212,422
CPU 414-3PN/DP10 ms---TP 177BSmall112 MBaudET 200M DP1212,522
CPU 317-2DP10 ms---------012 MBaudET 200M DP1212,522,6
CPU 317-2DP10 ms---------01,5 MBaudET 200M DP1213,122,8
CPU 414-3PN/DP10 ms---------012 MBaudET 200M DP1212,921,3
CPU 414-2DP10 msCP 443-5 ExtTP 177BSmall112 MBaudET 200M DP1213,221,9
CPU 414-2DP10 msCP 443-5 ExtTP 177BSmall112 MBaudET 200M DP16212,423,2
CPU 414-3PN/DP10 ms---------01,5 MBaudET 200M DP1212,722,5
CPU 414-2DP10 msCP 443-5 Ext------01,5 MBaudET 200M DP1213,122,4
CPU 414-2DP10 msCP 443-5 ExtPG---112 MBaudET 200M DP1213,122,2
CPU 414-2DP10 msCP 443-5 Ext------012 MBaudET 200M DP11613,422,5
CPU 414-3PN/DP10 ms---TP 177BLarge112 MBaudET 200M DP1213,121,9
CPU 317-2DP10 ms---PG---112 MBaudET 200M DP1213,122,7
CPU 414-2DP10 msCP 443-5 Ext------012 MBaudET 200M DP121322
CPU 414-2DP10 msCP 443-5 ExtTP 177BLarge112 MBaudET 200M DP1212,822,7
CPU 414-2DP10 msCP 443-5 ExtTP 177BSmall1012 MBaudET 200M DP121323,7
CPU 414-2DP10 msCP 443-5 ExtTP 177BLarge112 MBaudET 200M DP11613,423,1
CPU 414-3PN/DP10 ms---TP 177BLarge112 MBaudET 200S1213,523
CPU 414-3PN/DP10 ms---TP 177BSmall1012 MBaudET 200M DP1212,722,5
CPU 317-2DP10 ms---TP 177BLarge112 MBaudET 200M DP1213,122,6
1 |  2 |  3 |  4 |  5 |  6 ...300
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Name of columnDescription
CPU CPU type
CPUFW Firmware version CPU
Prg-Load Load due to program in OB1
CP CP type
CPFW Firmware version CP
Net-Load Net load type
HMI-PrgLoad Scale of HMI programs
Num Net-Load Number of net loads
DP Baudrate Baudrate on PROFIBUS DP
Slave DP slave type
Num slaves Number of DP slave stations
IO-Bytes IO bytes per station
T Rea min [ms] Minimum DP reaction time via process image[ms]
T Rea max [ms] Maximum DP reaction time via process image[ms]
Cycle time min[ms] Minimum OB1 cycle time[ms]
Cycle time avg[ms] Average OB1 cycle time[ms]
Cycle time max[ms] Maximum OB1 cycle time[ms]
T HMI upd. min [ms] Minimum update time on the HMI panel [ms]
T HMI upd. max [ms] Maximum update time on the HMI panel [ms]
T HMI op. min [ms] Minimum operating time on the HMI panel [ms]
T HMI op. max [ms] Maximum operating time on the HMI panel [ms]
T PPC upd. min [ms] Minimum update time on the PanelPC [ms]
T PPC upd. max [ms] Maximum update time on the PanelPC [ms]
T PPC op. min [ms] Minimum operating time on the PanelPC [ms]
T PPC op. max [ms] Maximum operating time on the PanelPC [ms]
ID ID
 
siemens.com Global Website |
© Siemens AG 2002-2024 -
Corporate Information | Privacy Policy | Terms of Use | Digital ID