SIEMENS


Skip over Site Identifier

Healthcare USA

Close Site Id Layer

neu

 

about

Version: V6.0
DB: Jul 2008
 

related

Version: V7.0 DB: Jun 2009
Version: V2.0 DB: Apr 2006
Version: V3.0 DB: Sept 2006
Version: V4.0 DB: Jun 2007
Version: V8.1 DB: Jan 2011
Version: V9.0 DB: Jul 2015


Skip over Language Switch

Language switch

  • English
  • Deutsch
  • Français
  • Italiano
  • Español
  • 中文

Skip over Generic Navigation

  • Contact

Skip over Help

Help


Auswahl der Konfiguration
IO-ControllerNetzPeripherie
CPU
nichts ausgewählt
 CPU 315-2DP
 CPU 317-2PN/DP
 CPU 319-3PN/DP
 CPU 414-2DP
 CPU 414-3PN/DP
 CPU 416-3PN/DP
 PC477B-RTX
 PC477B-HMI/RTX
 Sinumerik 840D SL NCU 720.2 PN
 PC677B-RTX
 PC677B-HMI/RTX
CP
nichts ausgewählt
 ---
 CP 443-1 Adv (EX41)
 CP 343-1 (EX30)
 CP 443-1 (EX20)
 CP 1616
Last durch Programm
nichts ausgewählt
 10 ms
 50 ms
 150 ms
 10ms + LARGE
 10ms + ENHANCED
 50ms + LARGE
 50ms + ENHANCED
Last am Netz
nichts ausgewählt
 ---
 PG
 TP 177B
Anzahl der Netzlast-Geräte
nichts ausgewählt
 0
 1
 4
 7
HMI-Projektumfang
nichts ausgewählt
 ---
 Small
 Large
Netzanschluss
nichts ausgewählt
 wired
 SCALANCE W788-1RR
Anzahl der WLAN Clients
nichts ausgewählt
 0
 1
 16
Typ
nichts ausgewählt
 ET 200S PN
 ET 200M PN
Anzahl der Stationen
nichts ausgewählt
 1
 16
 32
 60
EA-Bytes pro Station
nichts ausgewählt
 2
 16
 30
 32
 
Leistungsvorgaben
ReaktionszeitenBedienzeitenAktualisierungszeiten
T Rea min [ms]
Kein Filter

must be of type integer
T Rea max [ms]
Kein Filter

must be of type integer
T Rea Alrm min[ms]
Kein Filter

must be of type integer
T Rea Alrm max[ms]
Kein Filter

must be of type integer
T HMI op. min [ms]
Kein Filter

must be of type integer
T HMI op. max [ms]
Kein Filter

must be of type integer
T PPC op. min [ms]
Kein Filter

must be of type integer
T PPC op. max [ms]
Kein Filter

must be of type integer
T HMI upd. min [ms]
Kein Filter

must be of type integer
T HMI upd. max [ms]
Kein Filter

must be of type integer
T PPC upd. min [ms]
Kein Filter

must be of type integer
T PPC upd. max [ms]
Kein Filter

must be of type integer
 
Gewählte Konfiguration
Programmlast:nichts ausgewählt
Anzahl der Netzlast-Geräte:nichts ausgewählt
HMI-Projektumfang:nichts ausgewählt
Anzahl der WLAN Clients:nichts ausgewählt
Anzahl der Stationen:nichts ausgewählt
EA-Bytes pro Station:nichts ausgewählt
 

Ergebnisse: 5764 von 5764      Ergebnisse herunterladen (*.csv)

Spalten anzeigen

CPUPrg-LoadCPNet-LoadNum Net-LoadHMI-PrgLoadNet-LinkNumWLANCellsDeviceNum devicesIO-BytesT Rea min [ms]T Rea max [ms]
CPU 416-3PN/DP10 ms---TP 177B1Smallwired0ET 200M PN1212,823,5
CPU 414-3PN/DP10 ms---TP 177B1Smallwired0ET 200M PN1212,924,3
CPU 414-3PN/DP10 ms---TP 177B7Smallwired0ET 200M PN121324
CPU 416-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN1212,924,1
CPU 416-3PN/DP10 ms---TP 177B7Smallwired0ET 200M PN121324,2
CPU 414-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN1213,424,4
CPU 416-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN1213,323,7
CPU 416-3PN/DP10 ms---TP 177B4Largewired0ET 200M PN1213,324,5
CPU 414-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN16213,224,3
CPU 416-3PN/DP10 ms---TP 177B1Smallwired0ET 200M PN1621324,2
CPU 414-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN1213,124,8
CPU 414-3PN/DP10 ms------0---wired0ET 200M PN1213,423,6
CPU 416-3PN/DP10 ms------0---wired0ET 200M PN1213,223,8
CPU 416-3PN/DP10 ms------0---wired0ET 200M PN1621324
CPU 414-3PN/DP10 ms------0---wired0ET 200M PN16213,324,6
CPU 416-3PN/DP10 ms---PG1---wired0ET 200M PN1213,324,4
CPU 414-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN16213,224,2
CPU 414-3PN/DP10 ms---TP 177B7Smallwired0ET 200M PN1621324,3
CPU 416-3PN/DP10 ms---TP 177B1Largewired0ET 200M PN16213,126
CPU 416-3PN/DP10 ms---TP 177B4Smallwired0ET 200M PN1621324,4
1 |  2 |  3 |  4 |  5 |  6 ...289
Close Contact Layer

Siemens Industry Online Support

Organisation

Siemens AG

DI CS FA DIL

Siemens Industry Online Support

Close Service Layer
Close Div Columns Layer
Name der SpalteBeschreibung
CPU CPU Typ
CPUFW Firmwarestand CPU
Prg-Load Last durch Programm im OB1
CP CP Typ
CPFW Firmwarestand CP
Net-Load Typ der Netzlast
Num Net-Load Anzahl Netzlasten
HMI-PrgLoad HMI Projektumfang
Net-Link Netzanschluss
Net-LinkFW Firmwarestand Netzanschluss
NumWLANCells Anzahl WLAN-Clients
Device IO-Device Typ
Num devices Anzahl IO-Device Stationen
IO-Bytes EA-Bytes pro Station
IO-Bytes PI Summe EA-Bytes über Prozessabbild
T Rea min [ms] minimale PN-Reaktionszeit über Prozessabbild[ms]
T Rea avg [ms] durchschnittliche PN-Reaktionszeit über Prozessabbild[ms]
T Rea max [ms] maximale PN-Reaktionszeit über Prozessabbild[ms]
Cycle time min[ms] minimale OB1 Zykluszeit[ms]
Cycle time avg[ms] durchschnittliche OB1 Zykluszeit [ms]
Cycle time max[ms] maximale OB1 Zykluszeit[ms]
PNIO_SendClock[ms] PN IO Sendetakt [ms]
T HMI upd. min [ms] minimale Aktualisierungszeit am HMI Panel [ms]
T HMI upd. avg [ms] durchschnittliche Aktualisierungszeit am HMI Panel [ms]
T HMI upd. max [ms] maximale Aktualisierungszeit am HMI Panel [ms]
T HMI op. min [ms] minimale Bedienzeit am HMI Panel [ms]
T HMI op. avg [ms] durchschnittliche Bedienzeit am HMI Panel [ms]
T HMI op. max [ms] maximale Bedienzeit am HMI Panel [ms]
T PPC upd. min [ms] minimale Aktualisierungszeit am PanelPC [ms]
T PPC upd. avg. [ms] typische Aktualisierungszeit am PanelPC [ms]
T PPC upd. max [ms] maximale Aktualisierungszeit am PanelPC [ms]
T PPC op. min [ms] minimale Bedienzeit am PanelPC [ms]
T PPC op. avg. [ms] durchschnittliche Bedienzeit am PanelPC [ms]
T PPC op. max [ms] maximale Bedienzeit am PanelPC [ms]
 
siemens.com Global Website |
© Siemens AG 2002-2024 -
Corporate Information | Privacy Policy | Terms of Use | Digital ID